6 FBI-Provided Solved Dataset #1
The results of Section 6 are based on searches of the sequestered dataset FBI-Provided Solved Dataset #1. This dataset consists of 516 operational probes collected from a particular type of crime. Examiners at the FBI annotated several of the probe images with EFS features, possibly with algorithm assistance. These examiners then confirmed the ground truth mate. All probes searched were a single sample depicting a region from a distal phalanx. EFS data provided with the probe image may include:
- Pattern classification
- Core locations (unconfirmed source)
- Delta locations (unconfirmed source)
- Minutia locations (unconfirmed source)
6.1 Failures
Table 6.1 shows the number of failures to create templates. Table 6.2 shows the number of failures to produce a candidate list.
Image Type | Content | Failures | Attempts |
---|---|---|---|
Exemplar | Image | 0 | 173 |
Probe | EFS | 0 | 285 |
Probe | Image | 0 | 516 |
Probe | Image + EFS | 0 | 516 |
Probe Content | Failures | Attempts |
---|---|---|
EFS | 0 | 285 |
Image | 0 | 516 |
Image + EFS | 0 | 516 |
6.2 CMC
6.2.1 Plots
6.2.1.1 All Probes
The CMC plots in Figure 6.1 show the FNIR of Neurotechnology+0122
when searching FBI-Provided Solved Dataset #1 against enrollment database where a single mated identity for each search probe was present. The plots are faceted by the mated impression type and whether probe EFS data was provided. Tabular versions of FNIR at select ranks can be viewed in Table 6.3.
6.2.1.2 Probes with EFS Data
Not all of the probes in the FBI-Provided Solved Dataset #1 dataset contain EFS data. The plot in Figure 6.2 shows the CMC over only the probes that contained EFS data. This plot also differs from Figure 6.1 with the inclusion of a line for probes where no image was provided when creating the probe template, meaning the only information available was EFS data. Only the region success location is shown.
6.2.2 FNIR at Select Rank
6.2.2.1 All Probes
The values in Table 6.3 correspond to Figure 6.1.
Probe Content | Rank 1 | Rank ≤ 2 | Rank ≤ 5 | Rank ≤ 10 | Rank ≤ 50 | Rank ≤ 100 |
---|---|---|---|---|---|---|
Image | 0.0349 | 0.0310 | 0.0213 | 0.0213 | 0.0174 | 0.0155 |
Image + EFS | 0.0329 | 0.0291 | 0.0194 | 0.0194 | 0.0155 | 0.0097 |
6.2.2.2 Probes with EFS Data
The values in Table 6.4 correspond to Figure 6.2.
Probe Content | Rank 1 | Rank ≤ 2 | Rank ≤ 5 | Rank ≤ 10 | Rank ≤ 50 | Rank ≤ 100 |
---|---|---|---|---|---|---|
EFS | 0.2912 | 0.2491 | 0.2140 | 0.1895 | 0.1474 | 0.1298 |
Image | 0.0281 | 0.0246 | 0.0246 | 0.0246 | 0.0211 | 0.0175 |
Image + EFS | 0.0246 | 0.0211 | 0.0211 | 0.0211 | 0.0175 | 0.0070 |
6.3 DET
6.3.1 Plots
6.3.1.1 All Probes
The DET plots in Figure 6.3 show the false positive and false negative identification rate tradeoffs of Neurotechnology+0122
when searching FBI-Provided Solved Dataset #1 against enrollment database where a single mated identity for each search probe was present. The plots are faceted by the mated impression type and whether probe EFS data was provided. Tabular versions of FNIR at select FPIR can be viewed in Table 6.5. Annotated values indicate similarity scores from the Region line, which are tabulated in Table 6.7.
6.3.1.2 Probes with EFS Data
Not all of the probes in the FBI-Provided Solved Dataset #1 dataset contain EFS data. The plot in Figure 6.4 shows the DET over only the probes that contained EFS data. This plot also differs from Figure 6.3 with the inclusion of a line for probes where no image was provided when creating the probe template, meaning the only information available was EFS data. Only the region success location is shown.
6.3.2 FNIR at Select FPIR
6.3.3 Similarity Score Thresholds at Select FPIR
The values in Table 6.7 correspond to similarity score thresholds observed at the select FPIR values from Table 6.5.
Probe Content | FPIR = 0.01 | FPIR = 0.02 | FPIR = 0.1 |
---|---|---|---|
Image | 136 | 125 | 103 |
Image + EFS | 138 | 128 | 108 |