This module contains functions for exporting effective efficiency datasets.
"""
from __future__ import annotations
import microcalorimetry.configs as configs
from microcalorimetry.math import rmemeas_extras, vna
from microcalorimetry._tkquick.gui_dtypes import SaveAsPath
from rmellipse import RMEProp, RMEMeas
import numpy as np
import warnings
from pathlib import Path
from datetime import datetime
__all__ = ['as_doteff', 'as_dotdut_s11']
def group_typed_uncertainties(params: RMEMeas) -> RMEMeas:
"""
Group uncertainty mechanisms in params by Type.
Any mechanism with a combine_id is assumed to be Type A.
Any mechanisms that doesn't have a type assigned is assumed to be
Parameters
----------
params : RMEMeas
Meas object to group uncertainty mechanisms.
Returns
-------
grouped : RMEMeas
Meas object with grouped uncertainties.
"""
# treat anything with a combine ID as type A, derived from statistical means
use = params.copy()
cc = use.covcats
if 'combine_id' in params.covcats.categories:
cc.loc[{'categories': 'Type'}][cc.loc[{'categories': 'combine_id'}] != ''] = 'B'
# anything that hasn't been assigned a Type yet is Type B
not_a_or_b = np.logical_and(
cc.loc[{'categories': 'Type'}] != 'A', cc.loc[{'categories': 'Type'}] != 'B'
)
if not_a_or_b.any():
print(
'Some uncertainty mechanisms not identified as type A or B, assigning as B.'
)
cc.loc[{'categories': 'Type'}][not_a_or_b] = 'B'
# assume anything with a combine id is Type A
# things that didn't have one would be grouped under uncategorized
grouped = rmemeas_extras.categorize_by(use, 'Type')
return grouped
[docs]
def as_dotdut_s11(
s11: configs.S11Like,
path: SaveAsPath,
device: str,
expansion_factor: float = 2.0,
):
"""
Export a device to a .dut file for 1 port s-parameters.
This is a cal services
Parameters
----------
s11 : configs.S11Like
Path to output file.
path : SaveAsPath
RMEMeas measurement s1p_c data.
device : str
Name of device.
expansion_factor : float, optional
If >1 will use the provided expansion factor.
If < 1, will calculate the confidence interval
(i,e 0.95 will calculate the 95% confidence interval.
Returns
-------
Path
Path to exported DUT file.
"""
data = configs.S11Like(s11).load()
# assign everythin got type B as default
data.create_empty_categories(['Type'])
data.covcats.loc[:, 'Type'] = 'B'
# assign type a inherted from primary standards
a_markers = ['Drift', 'trace', 'cables', 'cable', 'Cable', 'PCA', 'additive']
type_a_umechs = data.cov.umech_id[
[False] + [any([am in oi for am in a_markers]) for oi in data.umech_id]
]
data.covcats.loc[type_a_umechs, 'Type'] = 'A'
# propagate to real/imaginary
prop = RMEProp(sensitivity=True)
get_mag = prop.propagate(vna.linmag)
get_phs = prop.propagate(vna.phase)
# calculate mag and phase, than
mag = group_typed_uncertainties(get_mag(data)).sel(s='S11')
phs = group_typed_uncertainties(get_phs(data)).sel(s='S11') * 180 / np.pi
assert 'uncategorized' not in mag.umech_id
if expansion_factor < 1:
mag_expansion = max(
(mag.confint(expansion_factor, rad=True)[1] - mag.nom) / mag.stdunc(rad=True).cov
)
phase_expansion = max(
(phs.confint(expansion_factor, rad=True)[1] - phs.nom) / phs.stdunc(rad=True).cov
)
expansion_factor = float(np.round(mag_expansion, 2))
print(f'{device} .dut export using expansion factor {expansion_factor}')
# calculate phase and magnitude uncertainties
utot_mag = mag.stdunc(k=expansion_factor).cov
ua_mag = mag.usel(umech_id=['A']).stdunc(k=1).cov
ub_mag = mag.usel(umech_id=['B']).stdunc(k=1).cov
uc_mag = ub_mag * 0
utot_phs = phs.stdunc(k=expansion_factor, deg=True).cov
ua_phs = phs.usel(umech_id=['A']).stdunc(k=1, deg=True).cov
ub_phs = phs.usel(umech_id=['B']).stdunc(k=1, deg=True).cov
uc_phs = ub_mag * 0
with open(path, 'w') as f:
now = datetime.today().strftime('%d %b %Y')
f.write(f'! {device} {now}\n')
f.write(f'! Utot expansion factor = {expansion_factor}\n')
f.write(f'! ')
f.write(
'! Freq, |Gamma|, Arg(Gamma), Ub|G|, Un|G|, Uc|G|, Utot|G|, UbA(G), UnA(G), UcA(G), UtotA(G)\n'
)
fmt = '{:9.6f} {:7.5f} {:8.3f} {:7.5f} {:7.5f} {:7.5f} {:7.5f} {:8.3f} {:8.3f} {:8.3f} {:8.3f}\n'
for freq in mag.nom.frequency:
f.write(
fmt.format(
freq,
mag.nom.sel(frequency=freq),
phs.nom.sel(frequency=freq),
ub_mag.sel(frequency=freq),
ua_mag.sel(frequency=freq),
uc_mag.sel(frequency=freq),
utot_mag.sel(frequency=freq),
ub_phs.sel(frequency=freq),
ua_phs.sel(frequency=freq),
uc_phs.sel(frequency=freq),
utot_phs.sel(frequency=freq),
)
)
[docs]
def as_doteff(
output_path: SaveAsPath,
eta: configs.EtaLike,
s11: configs.S11Like,
sensor_name: str = None,
connect_number: int = None,
expansion_factor: float = 2,
frequency_decimals: int = 2,
eta_decimals: int = 4,
s11_abs_decimals: int = 4,
s11_angle_decimals: int = 2,
columns: int = 7,
):
"""
Generate a .eff file from an effective efficiency measurement.
These files contain an effective efficiency measurement, as well
as a reflection coefficient and an expression of uncertainty. Type A and
Type B uncertainties will be inferred from the objects covariance
metadata.
Exporting as a .eff file will lose
covariance information about the measurement.
Parameters
----------
output_path : SaveAsPath
File path to save to.
eta : configs.EtaLike
Effective efficiency of the sensor.
s11 : configs.S11Like
S11 data of the sensor.
sensor_name : str
Name of the sensor. If not provided, won't be included
in the output file.
connect_number : int
Connect number of the sensor. If not provided, won't be included
in the comment line.
expansion_factor : int, optional
Expansion factor of the total uncertainty. If >= 1, will use that
as the expansion factor. If < 1, then will calculate the confidence
interval of the provided fraction (e.g 0.95 will calculate the
95% confidence interval) using metadata of the uncertainty mechanisms.
frequency_decimals : int, optional
Decimals for reporting frequency, by default 2
eta_decimals : int, optional
Decimals for reporting the eta parameters, by default 4.
s11_abs_decimals : int, optional
Decimals for reporting the S11 absolute value, by default 4.
s11_angle_decimals : int, optional
Decimals for reporting the S11 angle vakule, by default 2.
columns : int, optional
Number of columns in the eff file. By default 7.
"""
eta_dat = configs.EtaLike(eta).load()
s11_dat = configs.S11Like(s11).load()
flist = eta_dat.cov.frequency
try:
s11_dat = s11_dat.sel(frequency=flist)
except KeyError:
print('Warning: missing frequencies in S11 data. Interpolating.')
s11_dat = s11_dat.interp(frequency=flist)
now = datetime.now()
now = now.strftime('%d-%b-%Y')
eta_dat = eta_dat[..., 0]
eta_nom = eta_dat.nom.copy()
eta_grouped = group_typed_uncertainties(eta_dat)
eta_uA = eta_grouped.usel(umech_id=['A']).stdunc(k=1).cov
eta_uB = eta_grouped.usel(umech_id=['B']).stdunc(k=1).cov
# if using the DOFs, the expansion factor might be slightly different
# for each frequency point. So, I'm picking the worst case scenario
# to report here.
if expansion_factor < 1:
eta_utot = eta_dat.confint(expansion_factor)[1] - eta_nom
expansion_factor = float(
np.max(eta_utot / eta_dat.stdunc(k=expansion_factor).cov)
)
# re calculate with the worst case
eta_utot = eta_dat.stdunc(k=expansion_factor).cov
del eta_dat, eta_grouped
# only need the nominal here
s11_nom = s11_dat.nom[:, 0]
s11_abs = np.abs(s11_nom)
s11_angle = np.angle(s11_nom, deg=True)
del s11_dat, s11_nom
data_line = [f'{{:{3 + frequency_decimals}.{frequency_decimals}f}}']
data_line += [f'{{:{2 + s11_abs_decimals}.{s11_abs_decimals}f}}']
data_line += [f'{{:{5 + s11_angle_decimals}.{s11_angle_decimals}f}}']
data_line += [f'{{:{2 + eta_decimals}.{eta_decimals}f}}'] * 4
data_line = (' ' * 7).join(data_line)
# print(data_line)
# calculate eta uncertainty
with open(output_path, 'w') as f:
def line(line: str, nl='\n'):
f.write(line + nl)
if sensor_name:
line(f'# Gamma and Effective Efficiency of {sensor_name}')
if connect_number:
line(f'# Eta: Connect {connect_number}')
line(f'# COL={columns}, File created {now}')
line(f'# ExpansionFactor={expansion_factor:.2f}')
line(
'# freq |Gam| arg(Gam) eta uA uB Utot'
)
for i, fi in enumerate(flist):
# print(s11_angle[i])
dli = data_line.format(
fi,
s11_abs[i],
s11_angle[i],
eta_nom.sel(frequency=fi),
eta_uA.sel(frequency=fi),
eta_uB.sel(frequency=fi),
eta_utot.sel(frequency=fi),
)
# print(dli)
if i == len(flist) - 1:
term = ''
else:
term = '\n'
line(dli, nl=term)