Analysis Configurations

This page contains schemas used in configuring analysis functions.

CorrectionFactorDataInputs

Defines a set of data corresponding to a combination of sensors used in a correction factor measurement.

type

object

additionalProperties

properties

  • special

correction-factor-measurements

  • standard

correction-factor-measurements

  • splitter

S11

correction-factor-measurements

Points to a DUT’s S-parameters, parsed RF sweep, and calorimeter sensitivity cofficients for a particular measurement.

properties

  • s11

S11

  • parsed_calibration

ParsedRFSweep

  • clrm_coeffs

ThermoelectricFitCoefficients

additionalProperties

False

RFSweepParserConfig

Settings needed to parsed an RFsweep for a sensor, not specific to any type of sensor.

type

object

properties

  • analysis_config

type

object

properties

  • instr_timing_tolerance

Used for determining the relative time delays between the instrument signals for finding the ‘correct’ RF switching time. A typical value is 5 seconds.

type

number

  • RF_off_time_offset_method

Method for determining the last time point in the averaging window. If ‘max_change’: look for a change in column values corresponding to the source being turned off. If ‘first_data_point’, pick the time when the RF source was turned off - instr_timing_tolerance.

type

string

enum

max_change, first_data_point

examples

max_change

  • RF_on_average_window

time window (in seconds) to average over when evaluating long timescale settled values.

type

number

  • stats_window_override

Override the statswindow (in seconds) to average over when evaluating long timescale RF off values.

type

number

Bolometer Parser Settings

RF sweep parser settings specific to a bolometer sensor.

type

object

properties

  • V_off_delay

What time should be fit to when determining ‘off’ point when fitting the fast off.

type

number

examples

0.37

  • V_off_function

What type of fit function to use when fitting to the fast off voltage of the sensor.

type

string

enum

single_sample, lin_plus_exp, linear

examples

linear

  • V_off_fit_time_window

The time window - relative to when power was turned off - to fit the data to. Should be large enough to capture the curve.

type

array

examples

1

20

items

type

number

maxItems

2

minItems

2

  • dependentRequired

ParsedDCSweep

type

object

properties

  • v

DCSweep

  • i

DCSweep

additionalProperties

DCSweep

ParsedRFSweep

Output of a parsed calibration measurement. Each output is a an RMEMeas object with shape (n,) where n is a coordinate dimension called (frequency) in GHz and the outputs are real valued numbers corresponding to the measurement result.

type

object

properties

  • e_off

Calorimeter thermopile voltages in RF off state.

RFSweep

  • e_on

Calorimeter thermopile voltages in RF on state.

RFSweep

  • E_off

Power inferred by the thermopile in calorimeters RF off state.

RFSweep

  • E_on

Power inferred by the thermopile in calorimeters RF on state.

RFSweep

  • zeta

Uncorrected effective efficiency of sensor 2 (internal DUT)

RFSweep

  • e_p2_off

Thermopile voltages of sensor at port 2 in RF off state.

RFSweep

  • e_p2_on

Thermopile voltages of sensor at port 2 in RF on state.

RFSweep

  • p2_fast

RF power measured by sensor 2 (internal DUT) nn during the fast RF off portion of a frequency point.

RFSweep

  • p2_slow

RF power measured by sensor 2 (internal DUT) nn during the slow RF on portion of a frequency point

RFSweep

  • p3_fast

RF power measured by sensor 3 (external sidearm) nn during the fast RF off portion of a frequency point.

RFSweep

  • p3_slow

RF power measured by sensor 3 (external sidearm) nn during the slow RF on portion of a frequency point

RFSweep

  • p2dc_on

RF power measured by sensor 2 (internal DUT) nn during the fast RF off portion of a frequency point.

RFSweep

  • p2dc_off_fast

RF power measured by sensor 2 (internal DUT) nn during the fast RF off portion of a frequency point.

RFSweep

  • p2dc_off_slow

RF power measured by sensor 2 (internal DUT) nn during the slow RF on portion of a frequency point

RFSweep

additionalProperties

False

Historical Eta Measurments List

Describes historical Eta measurements to be used when calculating/reviewing Eta measurements.

type

object

properties

  • additionalProperties

All properties are dictionaries that describe each dataset

properties

  • datamodel

Eta