2. Error Codes¶
CODE |
ERROR |
COMMENT |
---|---|---|
5001 |
Override Error: Abstract class called |
NISTObject_class: This error occurs when the parent instance of a method that must be overridden is called. A child override instance should be called instead |
5002 |
The invalid message string % was received by module %s |
NISTCloneableModule.lvlib:Main.vi. Error thrown when the default case of the queued message handler is called. An unhandled message was inserted into the queue |
5004 |
Plugin class file not found at path: %s |
Check plugin .ini file for properly formatted relative path to class and check that the specified plugin class exists. Each plugin has a .ini file which contains a path to the class file itself. This error indicates that the class file was not found at the path indicated in the ini file |
CODE |
ERROR |
COMMENT |
---|---|---|
21001 |
Improper channel name %s. Must be Channel 1 through Channel 4 |
The OScope channel names must be specific to the scope class |
21002 |
Trigger Type %s is not yet supported |
This Trigger type will require the addition of an IVI extended class to the module |
21003 |
The scope module is not connected to the oscilloscope. Call Initialize to connect to the Oscope |
|
21004 |
Acquisition type %s is not supported by this oscilloscope |
CODE |
ERROR |
COMMENT |
---|---|---|
22001 |
Clock Name: %s Not Found |
Configure Clock command passed a clock name that was not found in the array of module clock properties |
22002 |
Unsupported Clock Type %s |
The Named Clock has a clock type that is not handled by the configure clocks method |
22003 |
Unable to Synchronize Timing System to Clock Reference. Be sure a cable is connected from the clock reference output to the ClkIn of the timing card |
The timing card uses a PLL to synchronize to an external timing reference (GPS, 1588, ETc.) Generally this is a 10 MHz clock input. |
22004 |
Trigger Name: %s Not Found |
Configure Trigger command passed a trigger name that was not found in the array of module trigger properties |
22005 |
Unsupported Trigger Type %s |
The Named Trigger has a trigger type that is not handled by the configure triggers method |
22006 |
Trigger Name %s is not a %s trigger type. Check the INI file |
The Named Trigger has a trigger type that does not match the trigger type being handled. |
22007 |
Trigger Name %s Timestamping has not been Enabled |
An attempt to read a trigger timestamp was made to a trigger which has not had timestamping enabled |
22008 |
Warning: Windows clock synchronization can only occur is LabVIEW is being run as administrator. Either:1) Ensure LabVIEW was started with Run As Administrator OR 2) Open Sync Module Settings and disable SyncWinClk. |
|
22009 |
Reference Clock Not Present: Status = %s |
The Reference Clock is not operating |
22010 |
Time out < %d ms while waiting for Sync Loop to stop |
The Sync look was requested to stop in the indicated time but for some reason did not. |
CODE |
ERROR |
COMMENT |
---|---|---|
23001 |
Channel Name: %s Not Found |
a command passed a channel name that was not found in the array of channel properties |
23002 |
Invalid Sample Clock Type %s selected |
This hardware requires a sample clock source and selected type is not available. |
23003 |
%d Pretrigger samples can only work with a Reference trigger source |
Either set the pretrigger samples to 0 or set the Trigger source to Reference. |
23004 |
Invalid or unknown trigger source %s |
Trigger sources can be Edge, Immediate, or reference. |
CODE |
ERROR |
COMMENT |
---|---|---|
24001 |
Trigger type %s is not supported by this hardware |
attempted to configure a trigger type that is not handled by the hardware being used. |
24501 |
Multiband function class, handle %s does not have equal number of frequency, Damping, Index and phase elements |
The confuration elements for multiband oscillators must have the same number of elements for each channel |
CODE |
ERROR |
COMMENT |
---|---|---|
25001 |
Warning: Cannot Change Configuration while Analysis is running |
User attempted to access the Analysis Configuration while an analysis was in progress |
25002 |
Unsupported Test Type: %s |
Support for this test type has not beed created yet |
CODE |
ERROR |
COMMENT |
---|---|---|
26001 |
Operation mode %s is only compatible with AC |
The user selected an AC-only operation mode, but attempted to treat the device as a DC system. The configuration was cancelled. |
26002 |
Operation mode %s is only compatible with DC |
The user selected a DC-only operation mode, but attempted to treat the device as an AC system. The configuration was cancelled. |
26003 |
Maximum AC Power Load %d is not above 0. |
The user attempted to set the maximum AC Power Load to 0 or a negative value, making it impossible for the load to dissipate power. |
26004 |
Slew Rates can only be controlled when load is in CR and CC operation modes. |
A function call was made to alter the slew rates of the function while the load was set to an operating mode in which the slew rates cannot be managed. |
26005 |
Operation mode % is not compatible with RLC operations. |
A function call was made to configure the RLC values of the device, though the device is in a non-RLC operation mode. |
26006 |
The %s of %#g was outside of the parameter’s range of %#g-%#g.. |
A parameter was selected that fell outside of its appropriate range; please set the parameter to fall within the range. |
26007 |
The module attempted to range check an invalid parameter %s. |
RangeCheck.vi attempted to run a check that didn’t exist. Check the string calling the variable and adjust it so it fits an appropriate value. |
26008 |
The number of loads %d must be equal to the number of phases %d. |
|
26009 |
The module received a command to initialize the device but is currently acquiring data. Abort the acquistion and close the reference in order to initialize a session to the device. |
|
26010 |
The number of phases required by the mode %d does not match the number of configured modes %d. |
|
26011 |
The number of phases configured %d must be less than or equal to 3. |
|
26012 |
Measurement Type %s is not currently supported. |
|
26013 |
Measurement Handle %s does not match Output Handle. |
|
26014 |
The %s cannot be zero. |
|
26015 |
The %s cannot be zero. |
|
26016 |
The configured fetch time %g seconds must be greater than the set aperture time of %g seconds. |
|
26017 |
Macros can only be edited if the NHR DC is connected and the visible Modules Element has a valid handle. |
CODE |
ERROR |
COMMENT |
---|---|---|
27001 |
The plugin’s acquisiton mode cannot be changed while acquiring data. Abort the acquisiton then change the acquisition mode. |
|
27002 |
The module received a command to initialize the device but is currently acquiring data. Abort the acquistion and close the reference in order to initialize a session to the device. |
|
27003 |
The module received a command to initiate acquisition but is currently acquiring data. Abort the acquistion in order to initiate another acquisition. |
|
27004 |
The module exceeded the amount of time specified waiting for the acquisition loop to enter the idle state. Increase the amount of time needed for the acquisition to complete or reduce the amount of data requested. |
CODE |
ERROR |
COMMENT |
---|---|---|
30001 |
Unknown module name %s |
Attemped to access an unknown or unsupported pluggable module |
30002 |
Loop stop condition name %s is unknown. Loop will be stopped |
Unrecognized loop stop condition names must force a stop to avoid infinate loops |
30003 |
Sync module not locked. Abort the test, wait for lock, and try again |
This framework must be synchronized before any test can be conducted” |
30102 |
Test Automation invalid Get argument %s |
The test script sent an argument that is not supported |
CODE |
ERROR |
COMMENT |
---|---|---|
31001 |
Bus Number not found %#d |
While searching the bus class for a particular bus number, the bus was not found in the class |
31002 |
Bus number %#d already exists |
While trying to add a bus, the bus number was found to already exist |
31003 |
Invalid Module type %#s |
While configuring modules, an unrecognized module type was found |