import logging
import threading
import time
logger = logging.getLogger(__name__)
[docs]
class PressureController():
'''
Abstract superclass for pressure controllers that provides timed dispensing
'''
def _log(self, level, message):
"""Use the attached API logger, including from dispensing threads."""
app_logger = getattr(getattr(self, 'app', None), 'logger', None)
getattr(app_logger if app_logger is not None else logger, level)(message)
[docs]
def timed_dispense(self,dispense_pressure,dispense_time,block=True):
'''
Perform a pressure dispense at pressure `dispense_pressure`, stopping after `dispense_time`.
This dispense can be interrupted by calling self.stop().
'''
self._log(
'info',
f'Starting timed pressure dispense: pressure={dispense_pressure}, '
f'duration={dispense_time} s, block={block}. Applying pressure command.',
)
self.active_callback = threading.Timer(dispense_time,self.stop)
self.set_P(dispense_pressure)
self._log('info', 'Timed dispense pressure command completed; starting stop timer.')
self.active_callback.start()
while not self.active_callback.is_alive():
time.sleep(0.01)
self._log('info', f'Timed dispense stop timer is running; pressure will be reset after {dispense_time} s.')
if block:
self.blockUntilStatusStopped()
self._log('info', 'Blocking timed pressure dispense completed.')
[docs]
def blockUntilStatusStopped(self,pollingdelay=0.2):
'''
block execution until the controller finishes a dispense
'''
if self.active_callback is not None:
status = self.active_callback.is_alive()
else:
status = False
while status:
time.sleep(pollingdelay)
status = self.active_callback.is_alive()
[docs]
def dispenseRunning(self):
'''
Returns true if a timed dispense is running, false otherwise.
'''
if self.active_callback is not None:
return self.active_callback.is_alive()
else:
return False
[docs]
def ramp_dispense(self,dispense_start_pressure, dispense_stop_pressure, dispense_time,const_time = 0,block=True):
'''
Perform a pressure dispense with a linear ramp in pressure between `dispense_start_pressure` and `dispense_stop_pressure`, stopping after `dispense_time`. This dispense can be interrupted by calling self.stop(). If const_time is set, the last `const_time` seconds of the dispense will be at constant pressure, with the ramp occurring in the remaining time.
'''
self._log(
'info',
f'Starting ramp pressure dispense: start_pressure={dispense_start_pressure}, '
f'stop_pressure={dispense_stop_pressure}, duration={dispense_time} s, '
f'ramp_duration={dispense_time - const_time} s, hold_duration={const_time} s, block={block}.',
)
self.start_time = time.time()
self.stop_flag = threading.Event()
self.active_callback = threading.Thread(target= self._ramp_pressure,args=(dispense_start_pressure,dispense_stop_pressure,dispense_time,const_time,self.stop_flag))
self._log('info', f'Applying initial ramp pressure command={dispense_start_pressure}.')
self.set_P(dispense_start_pressure)
self._log('info', 'Initial ramp pressure command completed; starting ramp thread.')
self.active_callback.start()
while not self.active_callback.is_alive():
time.sleep(0.01)
self._log('info', 'Pressure ramp thread is running.')
if block:
self.blockUntilStatusStopped()
self._log('info', 'Blocking ramp pressure dispense completed.')
def _ramp_pressure(self,dispense_start_pressure,dispense_stop_pressure,dispense_time,const_time,stop_flag):
try:
pressure_ramp_rate = (dispense_stop_pressure - dispense_start_pressure) / (dispense_time-const_time)
elapsed_time = time.time() - self.start_time
last_log_time = None
while elapsed_time<dispense_time and not stop_flag.is_set():
actual_elapsed = time.time() - self.start_time
elapsed_time = min(actual_elapsed, (dispense_time - const_time))
pressure = dispense_start_pressure + pressure_ramp_rate * elapsed_time
self.set_P(pressure)
if last_log_time is None or actual_elapsed - last_log_time >= 5.0:
phase = 'ramping' if actual_elapsed < dispense_time - const_time else 'holding'
self._log(
'info',
f'Pressure ramp progress: elapsed={actual_elapsed:.1f} s, '
f'configured duration={dispense_time} s, phase={phase}, '
f'commanded_pressure={pressure:g}. Actual pressure is not read back.',
)
last_log_time = actual_elapsed
time.sleep(0.05)
reason = 'external stop flag' if stop_flag.is_set() else 'ramp loop completed'
self._log('info', f'Pressure ramp ending: reason={reason}; resetting pressure to zero.')
self.stop()
except Exception as exc:
self._log('error', f'Pressure ramp thread failed: {type(exc).__name__}: {exc}')
raise
[docs]
def stop(self):
'''
Abort the current timed dispense action.
'''
self._log(
'info',
f'Stopping pressure dispense; callback running={self.dispenseRunning()}',
)
try:
self._log('info', 'Pressure stop: commanding pressure=0.')
self.set_P(0)
self._log('info', 'Pressure stop: zero-pressure command completed.')
try:
self.active_callback.cancel()
self._log('info', 'Pressure stop: timed dispense callback cancelled.')
except AttributeError: # this is a ramp thread, not a timer
self._log('info', 'Pressure stop: signalling ramp thread to stop, then reapplying pressure=0.')
self.stop_flag.set()
time.sleep(0.05)
self.set_P(0)
self._log('info', 'Pressure stop: ramp stop flag set and zero-pressure command completed.')
except Exception as exc:
self._log('error', f'Pressure stop failed: {type(exc).__name__}: {exc}')